IVSSH

Extra Thin Wall, Heat Resistant

Cable types
Extra Thin Wall, Heat Resistant

Material and Standard 

Conductor : Soft-annealed copper wires in compliance with  ISO 6722

Insulation : Vinyl (PVC) insulated.  In compliance with  ISO 6722 and RoHS Directive.

Application
High heat-resistant and low-tension wires with extra thin wall insulation for automobiles, motorcycles and other motor vehicles.ISO 6722 compliant.

Temperature
From -40
~100(Class B)

 

Nominal

 Cross 

Section

Conductor

Insulation

Overall Diameter

No. of 

Strands

Diameter

of  Strand

Outer Diameter

(max.)

Electric Resistance 

at  20℃ 

(max.)

Wall 

Thickness

(nom.) 

Wall 

Thickness

(min.) 

Maximum

mm²

 

mm

mm

mΩ/m

mm

mm

mm

0.3f

19

0.16

0.9

54.4

0.25

0.20

1.40

0.5f

19

0.19

1.1

37.1

0.28

0.22

1.60

0.75f

19

0.23

1.3

24.7

0.30

0.24

1.90